Development of RP-HPLC Method for Simultaneous Estimation of Alprazolam and Fluoxetine Hydrochloride in Pharmaceutical Tablet Dosage Form
S. K. Shah1*, S. C. Dangre2, N. B. Charbe2
1J. L. Chaturvedi College of Pharmacy, Electronic Zone Building, MIDC, Hingna road, Nagpur, Maharashtra, India.
2Shrarad Pawar College of Pharmacy, Hingna Road, Wanadongri, Nagpur-440016, Maharashtra, India.
*Corresponding Author E-mail: shah.sapan@rediffmail.com
ABSTRACT:
A new, simple, accurate and precise reversed phase high performance chromatographic method with UV detection was developed for the simultaneous quantitative estimation of Alprazolam (APZ) and Fluoxetine hydrochloride (FLX) in combined tablet dosage form. The method employed on reversed phase liquid chromatographic analysis using C18 column (4.6 × 250 mm, 5 µm). The Eluent was monitored by absorbance at wavelength 225 nm using a mixture of Acetonitrile and phosphate buffer (50:50 v/v) at pH 4.5 with a flow rate of 1.0 mL min-1. Calibration curves were found to be linear in the concentration range of 0.5-2.00 µg mL-1 and 40-160 µg mL-1 for APZ and FLX respectively. The proposed method was validated by testing its Linearity, recovery, repeatability and it was successfully employed for the rapid and specific simultaneous quantitative estimation of APZ and FLX in combined tablet dosage form
KEYWORDS: Alprazolam, Fluoxetine Hydrochloride, RP-HPLC, Method development, Validation, Marketed formulation.
INTRODUCTION:
Alprazolam (Fig.1) is 8-Chloro-1-methyl-6-phenyl-4H-1,2,4-triazolo(4,3-a)(1,4)benzodiazepine. Medicinally it is a short-acting drug in the benzodiazepine class used to treat anxiety disorders and as an adjunctive treatment for depression. It is also used as a medication to aid the beginning of treatment with SSRI type drugs, since these can cause anxiety in the initial stages of use [1]. Benzodiazepines produce a variety of effects by modulating the GABAA subtype of the GABA receptor, the most prolific inhibitory receptor within the brain [2].
Fluoxetine hydrochloride (Fig.2) is N-methyl-3-phenyl-3-[4-(trifluoromethyl)phenoxy]-propan-1-amine hydrochloride. Pharmaceutically it is antidepressant agent belonging to the selective serotonin reuptake inhibitors (SSRIs), is used to treat depression, bulimia nervosa, premenstrual dysphoric disorder, panic disorder and post-traumatic stress. According to the amines hypothesis, a functional decrease in the activity of amines, such as serotonin and norepinephrine, would result in depression; a functional increase of the activity of these amines would result in mood elevation [3].
Literature survey reveals the availability of HPLC and spectroscopic methods for the individual analysis of alprazolam and fluoxetine. However, no single method is reported for their simultaneous estimation in combined dosage form. Present work emphasizes simple, reproducible, precise and RP-HPLC quantitative method for simultaneous estimation of alprazolam and fluoxetine in combination, using UV-spectroscopy and HPLC techniques[4-7].
MATERIALS AND METHOD:
1. Chemicals and reagents:
Pharmaceutical grade of FLX and APZ were kindly supplied by Sun Pharmaceutical Industries, Silvassa, Gujarat, India and Unichem labrotraries, Baddi, Himachal Pradesh, India respectively. HPLC grade water, methanol and acetonitrile were purchased from Merck Chemicals Mumbai. Analytical grade of hydrochloric acid, o -phosphoric acid and potassium dihydrogen phosphate were used in present research work. Commercially available Fluwel (Bestochem Formulation, India) capsules claimed to contain 0.25 mg alprazolam and 20 mg fluoxetine were procured from local market.
2. Chromatographic system and conditions:
Chromatographic work was carried on Shimadzu HPLC system (Kyoto, Japan) having in-built degasser unit (DGU 14A), mixer unit (FCV 10AL) attached to the solvent delivery unit with low-pressure gradient pump (LC-10 AT), Rheodyne injector port (2E, 7725i, 20 µl loop), column oven (CTO 10AS) and UV/VIS detector (SPD 10 AVp). The mobile phase contains acetonitrile and potassium dihydrogen phosphate buffer adjusted to pH 4.5 with o -phosphoric acid in the ratio 50:50 (v/v) at the flow rate of 1.0 mL/min. The mobile phase was filtered through 0.2 μm membrane filter. Detection was monitored at 225 nm at ambient temperature.
3. Standard stock solutions:
Accurately weighed amount of APZ (100 mg) and FLX (100 mg) were transferred to 100 mL of volumetric flasks separately and diluted up to the mark with 0.1 M methanolic hydrochloric acid.
4. Sample preparation:
Twenty tablets were accurately weighed; average weight was calculated and finely powdered. A powder equivalent to 25 mg of FLX was transferred to 25 mL of volumetric flask and sonicated with 20 mL methanol for 15 min and diluted up to the mark. The solution was further diluted with mobile phase to get the concentration of 80 µg/mL of FLX and 1µg/mL of APZ. The sample solution was then filtered using 0.45 μ filter (Millipore, Milford, MA). A 20 μL volume of sample solution was injected into HPLC. The peak areas for the drugs were measured at 225 nm and amounts of APZ and FLX were determined using the related linear regression equations.
5. Linearity studies:
An aliquot portion of the standard stock solution of APZ and FLX were further diluted with mobile phase to get the series of concentration of 0.5-2 µg/mL for APZ and 40-160 µg/ml for FLX. The peak area was plotted against the corresponding concentrations to obtain the calibration graphs.
6. Recovery studies:
The accuracy of the proposed method was evaluated by the addition of a standard drug solution to a pre-analysed sample solution at three different concentration levels 80, 100 and 120 % for both drugs.
Sample solutions of APZ (125 µg mL-1) and FLX (1000 µg mL-1) was prepared and aliquots of 8 mL were transferred to 100 mL of three volumetric flasks containing 64, 80 and 96 µg mL-1 of FLX and another containing 0.8, 1 and 1.2 µg mL-1 of APZ from standard stock solution (1000 μg mL-1). Mobile phase was then added to make up the volume, giving final concentration of 144, 160 and 176 μg mL-1 of FLX and 1.8, 2 and 2.2 μg mL-1 of APZ.
7. LOD and LOQ:
All chromatograms were examined to determine if compounds of interest co-eluted with each other or with any additional excipients peaks. Marketed formulations were analyzed to determine the specificity of the optimized method in the presence of common capsule excipients. Limit of detection (LOD) and limit of quantitation (LOQ) were estimated from the signal-to-noise ratio. LOD and LOQ were calculated using 3.3σ/s and 10σ/s formulae, respectively, where, σ is the standard deviation of the peak areas and s is the slope of the corresponding calibration curve.
TABLE 1: OBSERVATION TABLE FOR STANDARD CALIBRATION CURVE OF FLX AND APZ
|
Sample no. |
Concentration (1:80 µg/mL) |
Peak Area (Mean ± SD) n=3 |
||
|
APZ |
FLX |
APZ |
FLX |
|
|
1 |
0.50 |
40 |
15.36 ± 0.2 |
317.85 ± 4.58 |
|
2 |
0.75 |
60 |
22.00 ± 0.15 |
456.29 ± 6.15 |
|
3 |
1.0 |
80 |
30.64 ± 0.33 |
623.30 ± 1.74 |
|
4 |
1.25 |
120 |
44.5 ± 0.60 |
889.68 ± 0.76 |
|
5 |
1.50 |
160 |
60.49 ± 2.03 |
1245.6 ± 41.60 |
TABLE 2: ANALYSIS DATA AND RECOVERY
|
Sample |
Statistical data |
% Label claim |
|||||
|
APZ |
FLX |
||||||
|
Standard laboratory mixture |
Mean |
98.00 |
99.18 |
||||
|
SD |
0.80 |
0.47 |
|||||
|
% RSD |
0.81 |
0.48 |
|||||
|
Marketed formulation sample |
Mean |
96.70 |
99.46 |
||||
|
SD |
1.93 |
0.12 |
|||||
|
% RSD |
1.97 |
0.12 |
|||||
|
Recovery studies |
Level |
80 % |
100 % |
120 % |
80 % |
100 % |
120 % |
|
Mean |
99.60 |
96.40 |
98.00 |
98.33 |
99.83 |
98.66 |
|
|
SD |
0.61 |
0.88 |
0.39 |
0.88 |
0.76 |
0.38 |
|
|
% RSD |
0.65 |
0.95 |
0.40 |
0.95 |
0.82 |
0.41 |
|
RESULTS AND DISCUSSION:
During the optimization of HPLC method, two columns (HI-Q Sil C18 5μm; 250 mm × 4.6 mm and Inertsil ODS C18 5 μm; 150×4.6 mm), two organic solvents (acetonitrile and methanol), two buffers (acetate and phosphate) at two different pH values (3 and 4.5) were tested. Initially, acetonitrile (100%), Acetonitrile: Water (70:30 v/v ), Acetonitrile: Buffer (70:30v/v) (pH = 3), Acetonitrile :Buffer(70:30v/v) (pH = 4.5), In order to decrease the analysis time, column length was reduced from 250 to 150 mm. The mobile phase conditions were optimized so the peak from the first-eluting compound did not interfere with those from the solvent, excipients. Other criteria, viz. time required for analysis, appropriate k range (1 < k < 10) for eluted peaks, assay sensitivity, solvent noise were also considered. Finally a mobile phase consisting of a mixture of acetonitrile: phosphate buffer pH 4.5 adjusted with o-phosphoric acid in ratio 50:50 (v/v), was selected as mobile phase to achieve maximum separation and sensitivity. A flow rate of 1.0 mL/min gives an optimal signal to noise ratio with a reasonable separation time. Using a reversed phase C18 column, the retention times for APZ and FLX were observed to be 1.89, 4.04, 5.19 min, respectively. Total time of analysis was less than 10 min. The chromatogram at 225 nm showed a complete resolution of all peaks [Figure 3].
Validity of the analytical procedure as well as the resolution between different peaks of ensured by system suitability test. All critical parameters tested met the acceptance criteria on all days. As shown in the chromatogram, all three analytes are eluted by forming symmetrical single peaks well separated from the solvent front [Figure 3]. The correlation coefficients (r 2) were found to be greater than 0.999 (n=6) in all instances. The results of calibration studies are summarized in [Table 1]. The proposed method afforded high recoveries for APZ and FLX capsules. Recovery studies was calculated by formula, % recovery= (T-A) x 100 where, T is total amount of the drug estimated, A is the amount of drug contributed by tablet powder and S is the amount of pure drug added. The results of the recovery studies for both APZ and FLX were found to be around 99-101 % [Table 2]. It indicated that methods are free from interference form excepients.
Precision of the analytical method was found to be reliable based on % RSD (< 2%) corresponding to the peak areas and retention times. Results show that % RSD values were less than 2, for intra-day and inter-day precision. Hence, proposed method was found to be precise for all the two drugs. In all deliberately varied conditions, the % RSD of retention times of APZ and FLX were found to be well within the acceptable limit.
From the above results it can be concluded that the developed HPLC method is simple, specific, accurate and precise for the simultaneous determination of APZ and FLX from tablet. The developed method provides good resolution between APZ and FLX. It was successfully validated in terms of system suitability, linearity, range, precision, accuracy, specificity, LOD and LOQ in accordance with ICH guidelines. Thus, the described method is suitable for routine analysis and quality control of pharmaceutical preparations containing these drugs either as such or in combination.
Fig. 3: Chromatogram of APZ and FLX in laboratory mixture sample
Fig.4: Chromatorgram of APZ and FLX in marketed formulation sample
ACKNOWLEDGEMENT:
The authors are thankful to Dr. D. R. Chaple, Principal, J. L. Chaturvedi College of Pharmacy, Hingna road, Nagpur for providing laboratory facilities. The authors would also like to acknowledge Vama Pharma Limited, Nagpur, for providing the gift samples of pure drugs APZ and FLX which ensures base for actual work to perform.
REFERENCES:
1. Martindale: the Complete Drug Reference”, Pharmaceutical Press. London Ed by Kathleen Parfitt: 2000, 24th Ed, 200-210.
2. Perez-Lozano P, Garcia-Montoya E, Orriols A, Minarro M, Tico JR, Sune-Negre JM. Development and validation of a new HPLC analytical method for the determination of alprazolam in tablets. J Pharm Biomed Anal. 2004, Mar 10; 34(5), 979-87.
3. “The Merck index, An Encyclopedia of Chemicals, Drugs and Biologicals”,Ed by S.Budari,Susan, Merck research lab., Division of Merck and Co. INC., White house station. 2006, 14th Ed, 738-739
4. United States Pharmacopoeia, NF-19, Ed XXIV, 2000. 64 and 738-739.
5. Juan H, Zhiling Z, Huande L. Simultaneous determination of fluoxetine, citalopram, paroxetine, venlafaxine in plasma by high performance liquid chromatography-electrospray ionization mass spectrometry (HPLC-MS/ESI). J Chromatogr B Analyt Technol Biomed Life Sci. 2005, Jun 5;820(1),33-36.
6. Bueno F, Bergold AM, Froehlich PE. Assay of fluoxetine hydrochloride by titrimetric and HPLC methods. Boll Chim Farm. 2000, Nov-Dec; 139(6),256-9. Misztal G, Hopkala H. Determination of fluoxetine in human plasma using reserved phase HPLC. Pharmazie. 1997, Nov;52(11),854-6.
Received on 26.05.2012 Modified on 20.06.2012
Accepted on 04.07.2012 © RJPT All right reserved
Research J. Pharm. and Tech. 5(7): July 2012; Page 938-941